fix: 修复 Windows 下 Gateway 运行态误判导致重复拉起#173
Open
g1621146262-netizen wants to merge 2 commits intoqingchencloud:mainfrom
Open
fix: 修复 Windows 下 Gateway 运行态误判导致重复拉起#173g1621146262-netizen wants to merge 2 commits intoqingchencloud:mainfrom
g1621146262-netizen wants to merge 2 commits intoqingchencloud:mainfrom
Conversation
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
fix: 修复 Windows 下 Gateway 运行态误判导致重复拉起
问题描述
在 Windows 环境下,Gateway 状态检测逻辑会将“通过端口识别到 PID”作为运行态判断条件之一。
当 Gateway 实际已监听端口,但 PID 识别偶发失败时,会被误判为未运行,触发守护重复拉起,导致:
修复方案
调整 Windows 平台 check_service_status 逻辑:
即:当端口已通但未识别到 PID 时,返回 (true, None),避免误判为停止。
具体改动
影响范围